{"id":56097,"date":"2023-05-01T18:40:10","date_gmt":"2023-05-01T13:10:10","guid":{"rendered":"https:\/\/corpbiz.io\/learning\/?p=56097"},"modified":"2023-05-01T18:40:11","modified_gmt":"2023-05-01T13:10:11","slug":"bis-certification-for-flexible-cable-for-miner-cap-lamps","status":"publish","type":"post","link":"https:\/\/corpbiz.io\/learning\/bis-certification-for-flexible-cable-for-miner-cap-lamps\/","title":{"rendered":"BIS Certification for Flexible Cable for Miner Cap Lamps"},"content":{"rendered":"\n<p>The Indian\nstandard <strong><em>IS 2593:1984<\/em><\/strong> pens down the quality and testing norms for\nFlexible cables for miners&#8217; cap lamps. This standard outlines the requirements\nfor flexible cables used in miners&#8217; cap lamps comprising a battery with a\nprotective cover, a cable, and a headpiece with a light source. The standard\ndeals with the cables that connect the headpiece to the battery. Let\u2019s\nunderstand how to secure BIS certification for Flexible Cable for Miner Cap\nlamps.<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title ez-toc-toggle\" style=\"cursor:pointer\">Page Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 eztoc-toggle-hide-by-default' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/corpbiz.io\/learning\/bis-certification-for-flexible-cable-for-miner-cap-lamps\/#General_Requirements_under_IS_2593_1984\" >General Requirements under IS 2593:1984<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/corpbiz.io\/learning\/bis-certification-for-flexible-cable-for-miner-cap-lamps\/#Tests_to_Qualify_For_BIS_Certification_for_Flexible_Cable_for_Miner_Cap_Lamps\" >Tests to Qualify For BIS Certification for Flexible Cable for Miner\nCap Lamps<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/corpbiz.io\/learning\/bis-certification-for-flexible-cable-for-miner-cap-lamps\/#Marking_Norms_Concerning_BIS_Certification_for_Flexible_Cable_for_Miner_Cap_Lamps\" >Marking Norms Concerning BIS Certification for Flexible Cable for Miner\nCap Lamps<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/corpbiz.io\/learning\/bis-certification-for-flexible-cable-for-miner-cap-lamps\/#What_Types_Of_Documents_Are_Required_For_BIS_Certification_For_Flexible_Cable_For_Miner_Cap_Lamps\" >What Types Of Documents Are Required For BIS Certification For Flexible\nCable For Miner Cap Lamps?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/corpbiz.io\/learning\/bis-certification-for-flexible-cable-for-miner-cap-lamps\/#How_to_Secure_BIS_Certification_for_Flexible_Cable_for_Miner_Cap_Lamps\" >How to Secure BIS Certification for Flexible Cable for Miner Cap Lamps?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/corpbiz.io\/learning\/bis-certification-for-flexible-cable-for-miner-cap-lamps\/#Conclusion\" >Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"General_Requirements_under_IS_2593_1984\"><\/span>General Requirements under IS 2593:1984<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>According to\nIS 2593:1984, the conductor for the cables must be made of tinned copper and\nadheres to the norms of IS: 8130-1984 Class 5. However, there is an exception\nspecified below. These guidelines will serve as a basis for BIS certification\nfor Flexible Cable for Miner Cap lamps. <\/p>\n\n\n\n<p>It is vital\nto adhere to these standards to ensure the safety and effectiveness of miners&#8217;\ncap lamps. Cables conforming to IS 2593:1984 ensure peace of mind for miners\nwho spend hours in challenging light scenarios. Here are some notable testing\nfigures. <\/p>\n\n\n\n<ul><li>The amount of copper that can dissolve during\npersulphate testing of sample wires should not go beyond 7.5 g\/m2. <\/li><li>The resistance concerning each core&#8217;s\nconductor, adjusted to 20\u00b0C, must not surpass 3.4 ohms per 100 m of the final\ncable.<\/li><\/ul>\n\n\n\n<p>The\nconductor&#8217;s nominal cross-sectional area should be 1 mm and its overall\nformation should conform to IS: 8130-1984 Flexibility Class 5. The insulation\nmust be a general-service elastomeric material that conforms to IS: 6380-1984\nType IE 1.<\/p>\n\n\n\n<p>1.8 mm is\nthe minimum diameter of the center cord. The sheath material should be none\nother than an elastomeric compound that conforms to IS: 6380-1984 Type SE3. The\ncable&#8217;s overall diameter should be 9.0 mm, with a tolerance of 0.25 mm.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Tests_to_Qualify_For_BIS_Certification_for_Flexible_Cable_for_Miner_Cap_Lamps\"><\/span>Tests to Qualify For BIS Certification for Flexible Cable for Miner\nCap Lamps<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong><em>Type Tests: Type Tests Shall Encompass The Following:<\/em><\/strong><\/p>\n\n\n\n<ul><li>Persulphate test<\/li><li>Conductor resistance test<\/li><li>Annealing test<\/li><li>Test for the thickness of insulation and sheath<\/li><li>Tests for center strain cord<\/li><li>Physical tests for insulation and sheath<\/li><li>Voltage test<\/li><li>Checking the overall diameter of the cable<\/li><li>Resistance of sheath to fatty acids<\/li><li>Flammability test<\/li><\/ul>\n\n\n\n<p><strong><em>Acceptance\nTests: Acceptance tests will cover the followings:<\/em><\/strong><strong><em> <\/em><\/strong><\/p>\n\n\n\n<ul><li>Persulphate test<\/li><li>Conductor resistance test<\/li><li>Annealing test<\/li><li>Test for breaking load of center strain cord<\/li><li>Test for the thickness of insulation and sheath<\/li><li>Checking the overall diameter<\/li><li>Voltage test<\/li><\/ul>\n\n\n\n<p><strong><em>Routine Tests: Routine Tests Cover The Following<\/em><\/strong><\/p>\n\n\n\n<ul><li>Conductor resistance test<\/li><li>Voltage test<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Marking_Norms_Concerning_BIS_Certification_for_Flexible_Cable_for_Miner_Cap_Lamps\"><\/span>Marking Norms Concerning BIS Certification for Flexible Cable for Miner\nCap Lamps<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The cable\nshould have the Manufacturer&#8217;s name or trademark on a tape, or printed,\nindented, or embossed on the outer sheath. It should also be supplied in reels,\ndrums, or coils.<\/p>\n\n\n\n<p>The standard\ninformation should be stenciled on the reel or drum, or contained in a label\nattached to it. Additionally, the cable may bear the ISI Mark.<\/p>\n\n\n\n<p>To use the <strong>ISI Mark<\/strong>, the Manufacturer must\nobtain a BIS license from the Bureau of Indian Standards. The <strong>BIS<\/strong><sup><a href=\"https:\/\/www.bis.gov.in\/\"><strong>[1]<\/strong><\/a><\/sup> evaluates the manufacturing\ninfrastructure, quality control and testing capabilities, and production\nprocess to grant the license.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_Types_Of_Documents_Are_Required_For_BIS_Certification_For_Flexible_Cable_For_Miner_Cap_Lamps\"><\/span>What Types Of Documents Are Required For BIS Certification For Flexible\nCable For Miner Cap Lamps?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong><em>For BIS\n(Bureau of Indian Standards) registration, the following documents are\ntypically required:<\/em><\/strong><\/p>\n\n\n\n<ul><li>Application form<\/li><li>Manufacturer&#8217;s ISO\/IEC 17025 certificate or\nequivalent<\/li><li>Test reports from BIS-recognized labs<\/li><li>List of machinery and equipment used for\nmanufacturing<\/li><li>Manufacturing unit layout plan<\/li><li>Trademark registration certificate (if\napplicable)<\/li><li>Undertaking for compliance with BIS regulations<\/li><li>Quality control manual<\/li><li>Authorized Indian representative&#8217;s appointment\nletter (for non-Indian manufacturers)<\/li><li>Proof of payment of fees<\/li><\/ul>\n\n\n\n<p>It&#8217;s worth\nnoting that the exact document requirements may vary product-wise and other\nfactors.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_to_Secure_BIS_Certification_for_Flexible_Cable_for_Miner_Cap_Lamps\"><\/span>How to Secure BIS Certification for Flexible Cable for Miner Cap Lamps?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Securing BIS\nregistration is a game-changing decision for a company intending to uplift the\nquality of its products. The BIS is liable for harmonizing the safety as well\nas the quality of various products in India. Henceforth, securing this\ncertification can help companies foster customer trust and boost their market\nreach in India. <\/p>\n\n\n\n<p>However, securing this certification can be a little daunting considering the legalities and paperwork it follows. Let\u2019s have a glance over the procedure for securing <strong><a href=\"https:\/\/corpbiz.io\/bis-registration\">BIS certification<\/a><\/strong> for Flexible Cable for Miner Cap lamps.<\/p>\n\n\n\n<ul><li><em><strong>Pinpoint the Applicable Standard<\/strong><\/em><\/li><\/ul>\n\n\n\n<p>The first\nstep towards obtaining BIS certification for Flexible Cable for Miner Cap lamps\nis to pinpoint the relevant product standard. BIS encompasses nearly 19,000\nproduct standards, and businesses must be assured of which one covers their\nproduct. The standards are listed on the BIS web portal. <\/p>\n\n\n\n<ul><li><em><strong>Prepare the Mandatory Paperwork<\/strong><\/em><\/li><\/ul>\n\n\n\n<p>Once you\npinpoint what standard applies to your product, proceed to arrange the\nmandatory paperwork. <\/p>\n\n\n\n<p>The\npaperwork entails technical dossiers such as test reports, drawings, and\ncommercial documents, including bills of materials and invoices. It is\nimperative to ensure that none of the documents have misleading or inaccurate\ninformation to avert delayed processing or application rejection. <\/p>\n\n\n\n<ul><li><em><strong>Conduct Product Testing<\/strong><\/em><\/li><\/ul>\n\n\n\n<p>Product\ntesting is the most important step in this process. Applicants must ensure that\ntheir products meet the underlying quality norms by complying with mandatory\ntests performed by the BIS-approved laboratory. The timeline and cost of the\ntesting process will vary product-wise. <\/p>\n\n\n\n<ul><li><em><strong>Submit the Application<\/strong><\/em><\/li><\/ul>\n\n\n\n<p>Once all the\nmandatory paperwork and testing phase are completed, an applicant can furnish\nthe BIS application. The application filing and submission can be done offline\nor online. Make sure that information provided is free from error or inaccurate\ndetail or else your application will be cancelled. <\/p>\n\n\n\n<ul><li><em><strong>Follow Up With Authority<\/strong><\/em><\/li><\/ul>\n\n\n\n<p>After\nfurnishing the e-form, businesses need to track the application progress. The\nauthority may prompt the applicant to share some paperwork or information\nduring the vetting phase. <\/p>\n\n\n\n<p>The\napplicant must respond swiftly to such requests to avert delays. As soon as the\napplication is approved, the applicant will receive their certification and\nthus become eligible to sell their products in India.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>In conclusion, securing BIS certification for Flexible Cable for Miner Cap lamps can be a taxing but vital step for companies seeking to make their mark in the given market. By adhering to the above steps and meeting compliance with all applicable product norms, businesses can improve their chances of a hassle-free registration process.  It is also imperative to consult with some professionals or legal experts who can help you with this complicated registration process. With well-thought-out planning and preparation, businesses can obtain the certification and augment their market reach in and outside India.<\/p>\n\n\n\n<p class=\"text-left\"><b>Read Our Article<\/b>: <mark style=\"background: #fffd03 !important;\"><a href=\"https:\/\/corpbiz.io\/learning\/bis-isi-for-wires-cables\/\">A Complete Study Of BIS ISI For Wires &amp; Cables<\/a><\/mark><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Indian standard IS 2593:1984 pens down the quality and testing norms for Flexible cables for miners&#8217; cap lamps. This standard outlines the requirements for flexible cables used in miners&#8217; cap lamps comprising a battery with a protective cover, a cable, and a headpiece with a light source. The standard deals with the cables that [&hellip;]<\/p>\n","protected":false},"author":22,"featured_media":56098,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[243],"tags":[3545],"acf":{"service_id":"221"},"authorName":"Pankaj Tyagi","authorImageUrl":"https:\/\/corpbiz.io\/learning\/wp-content\/uploads\/2022\/01\/MicrosoftTeams-image-42.jpg","authorDescription":"Pankaj has a diverse experience of writing research papers, blog, and articles during his college time. Earlier, he was working as a tax consultant in a financial firm, but his interest in writing drives him to pursue a career in the writing field.","postViews":2226,"readingTime":4,"_links":{"self":[{"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/posts\/56097"}],"collection":[{"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/users\/22"}],"replies":[{"embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/comments?post=56097"}],"version-history":[{"count":2,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/posts\/56097\/revisions"}],"predecessor-version":[{"id":56100,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/posts\/56097\/revisions\/56100"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/media\/56098"}],"wp:attachment":[{"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/media?parent=56097"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/categories?post=56097"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/tags?post=56097"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}