{"id":56001,"date":"2023-04-29T18:32:07","date_gmt":"2023-04-29T13:02:07","guid":{"rendered":"https:\/\/corpbiz.io\/learning\/?p=56001"},"modified":"2023-04-29T18:34:22","modified_gmt":"2023-04-29T13:04:22","slug":"how-to-get-bis-certification-for-structured-wall-plastic-pipes","status":"publish","type":"post","link":"https:\/\/corpbiz.io\/learning\/how-to-get-bis-certification-for-structured-wall-plastic-pipes\/","title":{"rendered":"How To Get BIS Certification For Structured Wall Plastic Pipes?"},"content":{"rendered":"\n<p>A structured wall plastic pipe is the ideal choice for different plumbing and water management requirements. Increased strength, durability, and ability to withstand chemicals make these pipes stand out. Just like other plumbing pipes and fittings, these products are required to be manufactured as per BIS norms. An Indian Standard called <strong><em>IS 16098 (Part 1): 2013<\/em><\/strong> specifies the testing and quality requirements for such products. Read on to discover how you can obtain BIS certification for structured wall plastic pipes.<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title ez-toc-toggle\" style=\"cursor:pointer\">Page Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 eztoc-toggle-hide-by-default' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/corpbiz.io\/learning\/how-to-get-bis-certification-for-structured-wall-plastic-pipes\/#IS_16098_Part_1_2013_%E2%80%93_An_Indian_Standard_for_Structured_Wall_Pipes\" >IS 16098 (Part 1):2013 &#8211; An Indian Standard for Structured Wall Pipes<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/corpbiz.io\/learning\/how-to-get-bis-certification-for-structured-wall-plastic-pipes\/#Mandatory_Tests_to_Qualify_For_BIS_Certification_for_Structured_Wall_Plastic_Pipes\" >Mandatory Tests to Qualify For BIS Certification for Structured Wall\nPlastic Pipes<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/corpbiz.io\/learning\/how-to-get-bis-certification-for-structured-wall-plastic-pipes\/#Understanding_the_Marking_Requirements_Under_IS_16098_Part_1_2013\" >Understanding the Marking Requirements Under IS 16098 (Part 1): 2013<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/corpbiz.io\/learning\/how-to-get-bis-certification-for-structured-wall-plastic-pipes\/#Documents_to_Apply_For_BIS_Certification_for_Structured_Wall_Plastic_Pipes\" >Documents to Apply For BIS Certification for Structured Wall Plastic\nPipes<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/corpbiz.io\/learning\/how-to-get-bis-certification-for-structured-wall-plastic-pipes\/#How_To_Secure_BIS_Certification_For_Structured_Wall_Plastic_Pipes\" >How To Secure BIS Certification For Structured Wall Plastic Pipes?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/corpbiz.io\/learning\/how-to-get-bis-certification-for-structured-wall-plastic-pipes\/#Conclusion\" >Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"IS_16098_Part_1_2013_%E2%80%93_An_Indian_Standard_for_Structured_Wall_Pipes\"><\/span>IS 16098 (Part 1):2013 &#8211; An Indian Standard for Structured Wall Pipes<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>IS 16098 (Part 1): 2013 is\nan Indian standard formulated and approved by the Plastic Piping Systems\nSectional Committee and Civil Engineering Division Council, respectively. BIS\nhas adopted this standard and uses it to prepare testing requirements for\ngranting BIS certification. Have a look at some noteworthy norms of this standard.<\/p>\n\n\n\n<ul><li>This standard encloses the requirements for structured pipes and fittings having a smooth finish and being used in sewage and drainage.<\/li><li>It encompasses PVC-U structural wall pipes and fittings regardless of whether or not they have integral sockets or solvent cement welding joints.<\/li><li>Coming to measurement, products having a nominal diameter ranging from 110-1200mm fall under this standard.<\/li><li>This piping system can withstand rusting triggered by water having a wide pH range such as groundwater and wastewater. The manufacturers must take the Chemical and temperature resistance capability into account while producing pipes that carry wastewater or industrial discharges.<\/li><li>Polyvinyl chloride should be the founding material for such products. The manufacturers can add some additives in a permissible limit to this base material to meet underlying requirements for quality.<\/li><li>All manufacturers must adhere to the testing and inspection scheme underpinned by the BIS. This statistical quality requirement can be used in the generalized quality protocol for pipe production.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Mandatory_Tests_to_Qualify_For_BIS_Certification_for_Structured_Wall_Plastic_Pipes\"><\/span>Mandatory Tests to Qualify For BIS Certification for Structured Wall\nPlastic Pipes<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The following tests are recommended by the Indian Standard for the production of structured wall plastic pipes. These tests shall serve as the basis for securing the BIS certification.<\/p>\n\n\n\n<ul><li><strong><em>Melt flow rate<\/em><\/strong><\/li><li><strong><em>Dimensions of pipes and\nfittings<\/em><\/strong><\/li><li><strong><em>Resistance to internal\npressure<\/em><\/strong><\/li><li><strong><em>Oven test<\/em><\/strong><\/li><li><strong><em>Flexibility<\/em><\/strong><\/li><li><strong><em>Impact strength<\/em><\/strong><\/li><li><strong><em>Thermal stability<\/em><\/strong><\/li><li><strong><em>Water tightness<\/em><\/strong><\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Understanding_the_Marking_Requirements_Under_IS_16098_Part_1_2013\"><\/span>Understanding the Marking Requirements Under IS 16098 (Part 1): 2013<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Each pipe and fitting shall undergo standard marking as per the standard\u2019s norms. The colour scheme matters a lot while marking the pipe. The marking and pipe colour should be different to make the information as legible as possible. Refer to the standard for more information.<\/p>\n\n\n\n<p>Each pipe and fitting should reflect the standard ISI marking that vouches for product quality. The manufacturer must secure the BIS certification before bringing the practice of ISI marking into effect. The bureau accords a license after evaluating the production premise for compliance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Documents_to_Apply_For_BIS_Certification_for_Structured_Wall_Plastic_Pipes\"><\/span>Documents to Apply For BIS Certification for Structured Wall Plastic\nPipes<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Following are the\ndocuments to apply for BIS Certification for structured well plastic pipes:<\/p>\n\n\n\n<ul><li>Technical specs concerning pipes, fittings, and accessories.<\/li><li>List of available standards that support quality management system<\/li><li>Details of the testing lab present within the premises<\/li><li>Business-related documents such as factory licenses, business registration, etc.<\/li><li>Lab report accorded by the BIS-certified lab<\/li><li>Authorization letter from the business owner permitting an agent to address application filing formalities.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_To_Secure_BIS_Certification_For_Structured_Wall_Plastic_Pipes\"><\/span>How To Secure BIS Certification For Structured Wall Plastic Pipes?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Applying for a <strong><a href=\"https:\/\/corpbiz.io\/bis-registration\">BIS certification<\/a><\/strong> is a step toward ensuring that your products fulfil the underlying requirements for quality, safety, and reliability. The Bureau of Indian Standards accords this certification after performing an in-depth assessment of the product and production facility.&nbsp; Let\u2019s take a closer look at how you can apply for and obtain BIS Certification for Structured Wall Plastic Piping System:<\/p>\n\n\n\n<ul><li><strong><em>Step 1: Be Assured Of the Standard Covering Your Product<\/em><\/strong><\/li><\/ul>\n\n\n\n<p>Ascertaining which\nstandard covers your product is vital before you proceed with the application\nfiling. You can visit the BIS website to fetch information regarding the same. <\/p>\n\n\n\n<ul><li><strong><em>Step 2: Pass the Mandatory Testing Requirements<\/em><\/strong><\/li><\/ul>\n\n\n\n<p>This step is all about product testing and report generation. You are required to pick some samples randomly and send it to the certified lab for testing. Once your products are tested, secure the lab report for the same. The lab will perform the following tests.<\/p>\n\n\n\n<ul><li>Melt flow rate<\/li><li>Dimensions of pipes and\nfittings<\/li><li>Resistance to internal\npressure<\/li><li>Oven test<\/li><li>Flexibility<\/li><li>Impact strength<\/li><li>Thermal stability<\/li><li>Water tightness<\/li><\/ul>\n\n\n\n<ul><li><strong><em>Step 3: Complete the Application Filing Formalities<\/em><\/strong><\/li><\/ul>\n\n\n\n<p>This step requires the\napplicant to visit the <strong>BIS portal<\/strong><sup><a href=\"https:\/\/www.bis.gov.in\/\"><strong>[1]<\/strong><\/a><\/sup> and file an e-form concerning BIS\ncertification for structured wall plastic pipes. While filing, you would be\nprompted to provide some basic information as shown below:<\/p>\n\n\n\n<ul><li><strong><em>Testing capabilities<\/em><\/strong><\/li><li><strong><em>Plant address<\/em><\/strong><\/li><li><strong><em>Quality management system<\/em><\/strong><\/li><li><strong><em>Product detail and production process<\/em><\/strong><\/li><\/ul>\n\n\n\n<p>This would be followed by\nthe document uploading and fee submission. Take note that the fee shall also\ninclude the on-site charges.<\/p>\n\n\n\n<ul><li><strong><em>Step 4: Inspection<\/em><\/strong><\/li><\/ul>\n\n\n\n<p>This step is all about\ndocument checking and on-site inspection. The BIS officials will be responsible\nfor performing necessary checks to identify any loopholes in paperwork or the\nmanufacturing infrastructure. The inspection process also involves sample collection\nin which officials pick some specimens for testing if required.<\/p>\n\n\n\n<ul><li><strong><em>Step 5: Grant of Certification<\/em><\/strong><\/li><\/ul>\n\n\n\n<p>After inspecting the lab report and other documents, the authority will accord the BIS certification for structured wall plastic pipes provided there are no loopholes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Post securing BIS certification for structured wall plastic pipes, you will become eligible to use the ISI marking. If somehow your applicant confronts the authority\u2019s rejection, you will be required to follow the entire process again. If you want to avert that possibility, consult with Corpbiz\u2019s professionals without any hesitation.<\/p>\n\n\n\n<p class=\"text-left\"><b>Read Our Article<\/b>: <mark style=\"background: #fffd03 !important;\"><a href=\"https:\/\/corpbiz.io\/learning\/how-to-apply-for-bis-certification-in-india\/\">How To Apply For BIS Certification In India?<\/a><\/mark><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A structured wall plastic pipe is the ideal choice for different plumbing and water management requirements. Increased strength, durability, and ability to withstand chemicals make these pipes stand out. Just like other plumbing pipes and fittings, these products are required to be manufactured as per BIS norms. An Indian Standard called IS 16098 (Part 1): [&hellip;]<\/p>\n","protected":false},"author":22,"featured_media":56025,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[243],"tags":[3538],"acf":{"service_id":"221"},"authorName":"Pankaj Tyagi","authorImageUrl":"https:\/\/corpbiz.io\/learning\/wp-content\/uploads\/2022\/01\/MicrosoftTeams-image-42.jpg","authorDescription":"Pankaj has a diverse experience of writing research papers, blog, and articles during his college time. Earlier, he was working as a tax consultant in a financial firm, but his interest in writing drives him to pursue a career in the writing field.","postViews":2159,"readingTime":4,"_links":{"self":[{"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/posts\/56001"}],"collection":[{"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/users\/22"}],"replies":[{"embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/comments?post=56001"}],"version-history":[{"count":3,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/posts\/56001\/revisions"}],"predecessor-version":[{"id":56026,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/posts\/56001\/revisions\/56026"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/media\/56025"}],"wp:attachment":[{"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/media?parent=56001"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/categories?post=56001"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/tags?post=56001"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}