{"id":54153,"date":"2023-03-30T12:10:51","date_gmt":"2023-03-30T06:40:51","guid":{"rendered":"https:\/\/corpbiz.io\/learning\/?p=54153"},"modified":"2023-03-30T12:10:53","modified_gmt":"2023-03-30T06:40:53","slug":"bis-certification-for-fabricated-pvc-u-fitting","status":"publish","type":"post","link":"https:\/\/corpbiz.io\/learning\/bis-certification-for-fabricated-pvc-u-fitting\/","title":{"rendered":"BIS Certification for Fabricated PVC-U Fitting"},"content":{"rendered":"\n<p>Fabricated PVC-U Fittings\nare widely used in plumbing applications owing to their robust construction and\nprolonged service life. However, they are mostly used to carry portable water\nsupplies. As with other PVC plumbing pipes, these fittings need to be\nmanufactured in line with certain guidelines. Presently, these fittings fall\nunder the <strong>IS\n10124 (Parts 1 to 13):2009<\/strong><sup><a class=\"text-primary\" href=\"https:\/\/bis.gov.in\/wp-content\/uploads\/2019\/01\/IS-10124-Part-1-to-13-Product-Manual.pdf\"><strong>[1]<\/strong><\/a><\/sup> and their manufacturers are mandatorily\nrequired to secure the BIS license. Let\u2019s see how to apply for BIS certification\nfor fabricated PVC-U fitting.<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title ez-toc-toggle\" style=\"cursor:pointer\">Page Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 eztoc-toggle-hide-by-default' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/corpbiz.io\/learning\/bis-certification-for-fabricated-pvc-u-fitting\/#General_Requirements_under_IS_10124_Parts_1_to_13_2009_for_Fabricated_PVC-U_Fittings\" >General Requirements under IS 10124 (Parts 1 to 13): 2009 for\nFabricated PVC-U Fittings<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/corpbiz.io\/learning\/bis-certification-for-fabricated-pvc-u-fitting\/#Documents_to_Apply_For_BIS_Certification_for_Fabricated_PVC-U_Fitting\" >Documents to Apply For BIS Certification for Fabricated PVC-U Fitting<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/corpbiz.io\/learning\/bis-certification-for-fabricated-pvc-u-fitting\/#How_to_Secure_the_BIS_Certification_for_Fabricated_PVC-U_Fitting\" >How to Secure the BIS Certification for Fabricated PVC-U Fitting?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/corpbiz.io\/learning\/bis-certification-for-fabricated-pvc-u-fitting\/#Conclusion\" >Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"General_Requirements_under_IS_10124_Parts_1_to_13_2009_for_Fabricated_PVC-U_Fittings\"><\/span>General Requirements under IS 10124 (Parts 1 to 13): 2009 for\nFabricated PVC-U Fittings<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Bureau of Indian Standards\nadopted IS 10124 (Parts 1 to 13): 2009 to outline testing requirements for the\ngrant of a BIS license.&nbsp; Every fittings\nmanufacturer must follow the guidelines cited in the Standard to qualify for\nthe BIS ISI certification.<\/p>\n\n\n\n<p>This standard (Part 1)\nspecifies the requisites around the sizes, material, test, testing methods, and\nmarking of fabricated PVC-U fittings used for potable water supply and are\neasily connected to pipes mentioned under IS 4985 via solvent cement and\nelastomeric sealing.<\/p>\n\n\n\n<p>This specification\nencompasses fittings having sizes within the range of 20-630mm. The same\nstandard pens down the specification of pipe used for producing fabricated\nPVC-U fittings.<\/p>\n\n\n\n<p>The standard entails\nthirteen parts that elaborate specific requirements for different types of\nfittings. The parts in the series are highlighted as the following:<\/p>\n\n\n\n<ul><li>Part 1 General requirements<\/li><li>Part 2 Specific\nrequirements concerning sockets<\/li><li>Part 3 Specific\nrequirements concerning straight reducers<\/li><li>Part 4 Specific\nrequirements concerning caps<\/li><li>Part 5 Specific\nrequirements concerning equal tees<\/li><li>Part 6 Specific\nrequirements concerning flanged tail pieces with metallic flanges<\/li><li>Part 7 Specific\nrequirements concerning threaded adaptors<\/li><li>Part 8 Specific\nrequirements concerning 90\u00b0 bends<\/li><li>Part 9 Specific\nrequirements concerning 60\u00b0 bends<\/li><li>Part 10 Specific\nrequirements concerning 45\u00b0 bends<\/li><li>Part 11 Specific\nrequirements concerning 30\u00b0 bends<\/li><li>Part 12 Specific\nrequirements concerning 22 \u00bd\u00b0 bends<\/li><li>Part 13 Specific\nrequirements concerning 11 \u00bc\u00b0 bends<\/li><\/ul>\n\n\n\n<p>A Different class and\ncolor are assigned to each fitting that reflects its working pressure. The\ntable below highlights the same.<\/p>\n\n\n\n<table class=\"wp-block-table table table-bordered\"><tbody><tr><td>\n  Class of the fittings\n  <\/td><td>\n  Working pressure (MPa)\n  <\/td><td>\n  Marking color\n  <\/td><\/tr><tr><td>\n  Class 1\n  <\/td><td>\n  0.25 \n  <\/td><td>\n  Red\n  <\/td><\/tr><tr><td>\n  Class 2\n  <\/td><td>\n  0.4 \n  <\/td><td>\n  Blue\n  <\/td><\/tr><tr><td>\n  Class 3\n  <\/td><td>\n  0.6\n  <\/td><td>\n  Green\n  <\/td><\/tr><tr><td>\n  Class 4\n  <\/td><td>\n  0.8 \n  <\/td><td>\n  Brown\n  <\/td><\/tr><tr><td>\n  Class 5\n  <\/td><td>\n  1.0\n  <\/td><td>\n  Yellow\n  <\/td><\/tr><tr><td>\n  Class 6\n  <\/td><td>\n  1.25\n  <\/td><td>\n  Black\n  <\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>The fitting shall undergo\nthe following tests for quality assurance:<\/p>\n\n\n\n<ol><li>Opacity Test<\/li><li>Type Test<\/li><li>Short-Term Hydraulic Test<\/li><li>Production Routine Test<\/li><\/ol>\n\n\n\n<p>All fittings must be\nexplicitly marketed at an apt place with the fitting maker\u2019s mark, size, colour\nbased on class, and degree of bend. The labelling of the product should be in\naccordance with the relevant part.<\/p>\n\n\n\n<p>The ISI marking should be\nthere on each fitting, ensuring that the product has passed the required tests.\nThe manufacturer must secure the BIS registration from the BIS for the legal\nuse of ISI marking. The authority, after receiving the application for the\nlicense, shall vet the production facility for compliance and then grant the\nlicense.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Documents_to_Apply_For_BIS_Certification_for_Fabricated_PVC-U_Fitting\"><\/span>Documents to Apply For BIS Certification for Fabricated PVC-U Fitting<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Following are the\ndocuments required for BIS certification for fabricated PVC-U fitting:<\/p>\n\n\n\n<ul><li>Legal paperwork for\nproduction premises such as COI or partnership deed<\/li><li>Permit accorded by the\nlocal body if available<\/li><li>Trademark registration if\navailable<\/li><li>List of resources\nincluding machinery used for fittings production<\/li><li>Details pertaining to\nin-house testing capabilities and equipment<\/li><li>Production process\nflowchart<\/li><li>Pollution NOC<\/li><li>Fire NOC<\/li><li>An authorization letter\nfrom the company\u2019s owner permitting the agent to file an application.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_to_Secure_the_BIS_Certification_for_Fabricated_PVC-U_Fitting\"><\/span>How to Secure the BIS Certification for Fabricated PVC-U Fitting?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Applying for a BIS license\ninvolves various complicated steps. However, the section below will strive to\nmake things easier for you.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Step 1: Go To the BIS Website to File an E-Form<\/em><\/h3>\n\n\n\n<p>This will be your first\nstep. All you need is to head to the BIS portal and fill up the application\nthat allows for ISI registration. While filling up the e-form, you would come\nacross various fields relating to business, products, standards being followed,\nproduction, and testing capabilities.<\/p>\n\n\n\n<p>Do not miss out on these\ndetails and thus fill them out with legit detail to avert any chance of\ncancellation. Once you are done with this, proceed to upload the paperwork as\ncited in the section above. And lastly, submit the application fee to complete\nthe filing requirement.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Step 2: Checking Of Paperwork and Premises Inspection<\/em><\/h3>\n\n\n\n<p>This step shall begin with\nthe inspection undertakings performed by the BIS officials. The documents shall\nundergo thorough inspection for any non-conformity. Upon scrutinizing the\npaperwork, the officials will inspect the premises where production takes place.<\/p>\n\n\n\n<p>The vetting of the\nproduction facility shall be performed with respect to methods cited in the\nstandard. The inspection process will come as soon as the officials pick some\nproduct samples (fittings in this case) for lab inspection.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Step 3: Samples (Fittings) Testing And Lab Report Generation<\/em><\/h3>\n\n\n\n<p>The onus of performing\nstandardized tests on samples shall be on the certified lab picked by the BIS\nofficials. The lab will technically conduct the given tests for quality\nassurance.<\/p>\n\n\n\n<ul><li>Opacity Test<\/li><li>Type Test<\/li><li>Short-Term Hydraulic Test<\/li><li>Production Routine Test<\/li><\/ul>\n\n\n\n<p>Upon completion of these\ntests, the lab will proceed with report creation in which they will enclose\ntheir observations and findings concerning product quality and performance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Step 4: Grant of Certification<\/em><\/h3>\n\n\n\n<p>Based on the lab report, the authority will take the decision concerning the grant of the <strong><a href=\"https:\/\/corpbiz.io\/medical-device-registration\">BIS certification<\/a><\/strong> for fabricated PVC-U fittings. The certification shall only be awarded if the samples passed underlying testing requirements.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>In conclusion, we can say that the BIS certification for fabricated PVC-U fittings revolves around plenty of legalities that cannot be overlooked. Make sure to have an in-depth understanding of the applicable standard before applying for this license. This way you can avert any chance of non-compliance which leads to the application\u2019s cancellation.<\/p>\n\n\n\n<p><strong>Also Read<\/strong>:<br><a href=\"https:\/\/corpbiz.io\/learning\/bis-certification-for-injection-moulded-pvc-socket-fittings\/\">BIS Certification For Injection Moulded PVC Socket Fittings<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Fabricated PVC-U Fittings are widely used in plumbing applications owing to their robust construction and prolonged service life. However, they are mostly used to carry portable water supplies. As with other PVC plumbing pipes, these fittings need to be manufactured in line with certain guidelines. Presently, these fittings fall under the IS 10124 (Parts 1 [&hellip;]<\/p>\n","protected":false},"author":22,"featured_media":54156,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[243],"tags":[3344],"acf":{"service_id":"221"},"authorName":"Pankaj Tyagi","authorImageUrl":"https:\/\/corpbiz.io\/learning\/wp-content\/uploads\/2022\/01\/MicrosoftTeams-image-42.jpg","authorDescription":"Pankaj has a diverse experience of writing research papers, blog, and articles during his college time. Earlier, he was working as a tax consultant in a financial firm, but his interest in writing drives him to pursue a career in the writing field.","postViews":2292,"readingTime":4,"_links":{"self":[{"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/posts\/54153"}],"collection":[{"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/users\/22"}],"replies":[{"embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/comments?post=54153"}],"version-history":[{"count":2,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/posts\/54153\/revisions"}],"predecessor-version":[{"id":54155,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/posts\/54153\/revisions\/54155"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/media\/54156"}],"wp:attachment":[{"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/media?parent=54153"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/categories?post=54153"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/tags?post=54153"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}