{"id":1935,"date":"2020-01-06T13:42:49","date_gmt":"2020-01-06T13:42:49","guid":{"rendered":"https:\/\/corpbiz.io\/learning\/?p=1935"},"modified":"2024-07-02T18:34:20","modified_gmt":"2024-07-02T13:04:20","slug":"save-your-immovable-property-from-fire-apply-for-fire-department-noc","status":"publish","type":"post","link":"https:\/\/corpbiz.io\/learning\/save-your-immovable-property-from-fire-apply-for-fire-department-noc\/","title":{"rendered":"Save Your Immovable Property From Fire. Apply for Fire NOC"},"content":{"rendered":"\n<p class=\"has-drop-cap\">As per the\nreport released by the NCRB (National Crime Records Bureau), India in the year\n2017, the risk of \u201cfire\u201d accidents in India has been ranked fifth i.e. 3<sup>rd<\/sup>&nbsp;positions\nup from the last year\u2019s ranking. Fire accidents if not handled properly, may\nlead to a massive loss of life and assets. With a perspective to lessen these\nfire accidents, the government of India has made it mandatory for the buildings\nand other workplaces to have the&nbsp;<a href=\"https:\/\/corpbiz.io\/fire-department-noc-in-india\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Fire department NOC<\/strong><\/a>. The procedure of obtaining Fire NOC\nvaries from one state to another state. In this blog up, we will see in detail\nthat what is Fire NOC, where it is required and its applicability.<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title ez-toc-toggle\" style=\"cursor:pointer\">Page Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 eztoc-toggle-hide-by-default' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/corpbiz.io\/learning\/save-your-immovable-property-from-fire-apply-for-fire-department-noc\/#Fire_Department_NOC\" >Fire Department NOC<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/corpbiz.io\/learning\/save-your-immovable-property-from-fire-apply-for-fire-department-noc\/#Conditional_NOC\" >Conditional NOC<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/corpbiz.io\/learning\/save-your-immovable-property-from-fire-apply-for-fire-department-noc\/#What_are_the_Categories_for_which_fire_NOC_can_be_obtained\" >What are the Categories for which fire NOC can be obtained?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/corpbiz.io\/learning\/save-your-immovable-property-from-fire-apply-for-fire-department-noc\/#What_are_the_Documents_required_for_obtaining_Fire_NOC\" >What are the Documents required for obtaining Fire NOC?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/corpbiz.io\/learning\/save-your-immovable-property-from-fire-apply-for-fire-department-noc\/#What_is_the_Procedure_for_Obtaining_Fire_NOC\" >What is the Procedure for Obtaining Fire NOC?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/corpbiz.io\/learning\/save-your-immovable-property-from-fire-apply-for-fire-department-noc\/#What_are_the_alternative_fire_prevention_measures_other_than_the_Fire_NOC\" >What are the alternative fire prevention measures other\nthan the Fire NOC?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/corpbiz.io\/learning\/save-your-immovable-property-from-fire-apply-for-fire-department-noc\/#What_is_the_validity_period_of_the_Fire_Department_NOC\" >What is the validity period of the Fire Department NOC?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/corpbiz.io\/learning\/save-your-immovable-property-from-fire-apply-for-fire-department-noc\/#Types_of_No_Objection_Certificate_issued_by_the_authority\" >Types of No\nObjection Certificate issued by the authority<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/corpbiz.io\/learning\/save-your-immovable-property-from-fire-apply-for-fire-department-noc\/#Conclusion\" >Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Fire_Department_NOC\"><\/span>Fire Department NOC<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Respective\nstate\u2019s fire services are responsible for the issuance of fire NOC after\nverifying and checking the entire building resistance against the fire.\nFirstly, the authorities form the Fire Department will verify the commercial or\nresidential multi-story building of the applicant and after finding no\nobjection in the premises, issue the fire NOC. Any considerable height of more\nthan 15 meters shall get fire NOC from their respective state fire services.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Conditional_NOC\"><\/span>Conditional NOC<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The\nconditional NOC&nbsp;is issued before building construction, based on\ninspection of the builder\u2019s plan. It describes the structural details of the\nbuilding and indicates changes required if any. It also mentions various fire\nsafety, fire-fighting and fire evacuation measures, along with specific\ninformation, that needs to be incorporated into the building, for final NOC to\nbe valid. This would include the following:<\/p>\n\n\n\n<ul>\n<li>The condition of open spaces<\/li>\n\n\n\n<li>Structural material<\/li>\n\n\n\n<li>Design of staircases<\/li>\n\n\n\n<li>Specification of lifts<\/li>\n\n\n\n<li>Service ducts\/ shafts<\/li>\n\n\n\n<li>Electric power supply<\/li>\n\n\n\n<li>Wet rise cum down comer<\/li>\n\n\n\n<li>Fire detection system<\/li>\n\n\n\n<li>Fire alarm system<\/li>\n\n\n\n<li>Fire sprinkler system<\/li>\n\n\n\n<li>Public address system<\/li>\n\n\n\n<li>Portable fire extinguishers<\/li>\n\n\n\n<li>Fire safety plan<\/li>\n\n\n\n<li>Fire officer<\/li>\n\n\n\n<li>Training.<\/li>\n<\/ul>\n\n\n\n<p class=\"text-left\"><b>Read our article<\/b>:<mark style=\"background: #fffd03 !important;\"><a href=\"https:\/\/corpbiz.io\/learning\/online-fire-department-noc-application-procedure\/\">India Fire Department NOC \u2013 Application Procedure<\/a><\/mark><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_are_the_Categories_for_which_fire_NOC_can_be_obtained\"><\/span>What are the Categories for which fire NOC can be obtained?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong><em>Following are the categories of buildings for which we need to obtain the NOC \u2013<\/em><\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/corpbiz.io\/learning\/wp-content\/uploads\/2020\/01\/Infographics-for-Fire-Department-NOC-1024x768.png\" alt=\"Categories for which fire NOC \" class=\"wp-image-1966\" srcset=\"https:\/\/corpbiz.io\/learning\/wp-content\/uploads\/2020\/01\/Infographics-for-Fire-Department-NOC-1024x768.png 1024w, https:\/\/corpbiz.io\/learning\/wp-content\/uploads\/2020\/01\/Infographics-for-Fire-Department-NOC-300x225.png 300w, https:\/\/corpbiz.io\/learning\/wp-content\/uploads\/2020\/01\/Infographics-for-Fire-Department-NOC-768x576.png 768w, https:\/\/corpbiz.io\/learning\/wp-content\/uploads\/2020\/01\/Infographics-for-Fire-Department-NOC.png 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_are_the_Documents_required_for_obtaining_Fire_NOC\"><\/span>What are the Documents required for obtaining Fire NOC?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong><em>The applicant needs to serve following documents to the concerned state\nauthority of their respective state \u2013<\/em><\/strong><\/p>\n\n\n\n<ul>\n<li>Site Plan;<\/li>\n\n\n\n<li>Checklist certified by the Architect;<\/li>\n\n\n\n<li>Floor-wise plan;<\/li>\n\n\n\n<li>Basement floor plan;<\/li>\n\n\n\n<li>Terrace plan;<\/li>\n\n\n\n<li>Stilt\/Ground Floor Plan;<\/li>\n\n\n\n<li>Elevation Plan;<\/li>\n\n\n\n<li>Section Plan;<\/li>\n\n\n\n<li>Provisional \/ Revised Provisional NOC (Occupancy NOC application)<\/li>\n<\/ul>\n\n\n\n<p><strong><em>Note \u2013<\/em><\/strong><\/p>\n\n\n\n<ul>\n<li>These plans uploaded by the applicant must be authorised signed by the Builders\/Owners and authorized technical persons.<\/li>\n\n\n\n<li>In case there are any deviations or contraventions in any of the approved drawings, then under section 31 and 32 of the Fire Service Act, 1999, it can attract prosecution of builder, architect and site engineer.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_is_the_Procedure_for_Obtaining_Fire_NOC\"><\/span>What is the Procedure for Obtaining Fire NOC?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong><em>The procedure for obtaining Fire NOC varies from state to state, which\nis listed below:<\/em><\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Visit the official website<\/h3>\n\n\n\n<p>In case, the applicant wants to apply for the Fire NOC in Delhi, then he\/she needs to visit the official site.<\/p>\n\n\n\n<p><strong><em>The applicant needs to visit their respective state government website\nfor obtaining the Fire NOC.<\/em><\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Upload the Scanned Documents<\/h3>\n\n\n\n<p>Further,\napplicant will upload the scanned documents on the website, and the District\nFire Officer will assign the file to the Zonal Station fire officer. The\napplicant needs to provide the following details while submitting the\ndocuments:<\/p>\n\n\n\n<ol>\n<li>Name of the Building or organisation.<\/li>\n\n\n\n<li>Type of NOC<\/li>\n\n\n\n<li>Applicant\u2019s email address<\/li>\n\n\n\n<li>Address details<\/li>\n\n\n\n<li>District name<\/li>\n\n\n\n<li>Mobile number<\/li>\n\n\n\n<li>Type of building<\/li>\n\n\n\n<li>Height of the Building<\/li>\n\n\n\n<li>Plot area<\/li>\n<\/ol>\n\n\n\n<ul>\n<li>After this, the Station fire officer will inspect the premises \/buildings, and check whether the construction is fire-resistant or not. The report will be submitted online. After the evaluation of the documents, the District Fire Officers will escalate the report to the additional Director Fire services.<\/li>\n\n\n\n<li>In the next step, the concerned inspector will visit the site and verify that all the necessary types of equipment and machinery are installed or not.<\/li>\n\n\n\n<li>If the inspector is satisfied with the safety measures equipped in the building, in such case Inspector of the fire brigade of the state will issue the Fire Clearance certificate.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Pre-Construction Requirements for filing the Fire NOC \u2013<\/h3>\n\n\n\n<ul>\n<li>The applicant needs to furnish the following information such as<\/li>\n\n\n\n<li>The nature of business<\/li>\n\n\n\n<li>Address of the Business establishment<\/li>\n\n\n\n<li>Contact details<\/li>\n\n\n\n<li>Sanction plan depicting the fire fighting system.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Post-Construction requirements for filing the Fire NOC \u2013<\/h3>\n\n\n\n<ul>\n<li>After receiving the compliance report and declaration, the fire department officer will again visit the site and re-inspect the site and forward the recommendations the head of the department.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_are_the_alternative_fire_prevention_measures_other_than_the_Fire_NOC\"><\/span>What are the alternative fire prevention measures other\nthan the Fire NOC?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Obtaining the\nFire NOC is not enough for minimizing the fire breakouts; apart from this, you\nneed to install other fire prevention measures in the building.<\/p>\n\n\n\n<p><strong><em>Various Fire Prevention measure are listed below:<\/em><\/strong><\/p>\n\n\n\n<ul>\n<li>Separate area for smoking.<\/li>\n\n\n\n<li>Installment of fire extinguishers.<\/li>\n\n\n\n<li>Proper supervision of the cooking area and the pantry.<\/li>\n\n\n\n<li>Non-disturbance in ventilating facilities.<\/li>\n\n\n\n<li>Maintenance of electric wiring of the building whenever required.<\/li>\n\n\n\n<li>Reinstallment of the smoke or fire alarms.<\/li>\n\n\n\n<li>The owner of the building must have the National Building code of India, which ensures that all contingency measures are successfully installed in the building.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_is_the_validity_period_of_the_Fire_Department_NOC\"><\/span>What is the validity period of the Fire Department NOC?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Under Rule\n35, Pre-Construction is valid for a period of 5 years in case of residential\napartments and three years for non-residential apartments from the date of\nissue.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Types_of_No_Objection_Certificate_issued_by_the_authority\"><\/span>Types of No\nObjection Certificate issued by the authority<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ul>\n<li><strong>Provisional Certificate&nbsp;<\/strong>\u2013 after the evaluation of fire and life&nbsp;safety procedure&nbsp;is made by the inspector, the&nbsp;fire department&nbsp;suggests the applicant to establish certain fire and life safety mechanisms. The department issues a&nbsp;Provisional&nbsp;NOC.<\/li>\n<\/ul>\n\n\n\n<p>Provisional&nbsp;<strong>NOC is <\/strong>issued by\nthe department and it is <strong>a\nfire safety<\/strong> certificate temporarily given which is subject\nto the obedience by\nthe applicant according to\nthe recommendation made to him. Provisional NOC is valid for a definite period in which the applicant has to prepare to act in accordance with\nwith the recommendations.<\/p>\n\n\n\n<ul>\n<li><strong>Final NOC \u2013<\/strong>it is obligatory on the part of the applicant to apply for inspection of the implementations to the&nbsp;fire prevention&nbsp;authority. After the inspection is done the authority shall check and certify that the applicant is adhering with the recommendation and that all the installations are working in a satisfactory condition then final NOC is issued.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>In our\ninclination to occupy new homes and office spaces in a high-rise or multi-storied\nbuildings, we often fail to observe the fire-safety readiness of the premises\nwhich in future can risk the lives and property of many individuals. Therefore,\none must obtain the Fire NOC to prevent their property from any loss and\ndamages. If you are a builder, hotel owner or run a school or any educational\ninstitution and concerned about the fire safety of you building get the Fire\nNOC assistance or looking for the License,&nbsp;<a href=\"https:\/\/corpbiz.io\/\"><strong>Corpbiz<\/strong><\/a>&nbsp;is\nthe one-stop solution for you. Kindly contact for any information related to\nFire NOC.&nbsp;<\/p>\n\n\n\n<p class=\"text-left\"><b>Read our article<\/b>:<mark style=\"background: #fffd03 !important;\"><a href=\"https:\/\/corpbiz.io\/learning\/penalty-for-not-taking-noc-fire-department-delhi\/\">Penalty for not Taking NOC Fire Department Delhi<\/a><\/mark><\/p>\n","protected":false},"excerpt":{"rendered":"<p>As per the report released by the NCRB (National Crime Records Bureau), India in the year 2017, the risk of \u201cfire\u201d accidents in India has been ranked fifth i.e. 3rd&nbsp;positions up from the last year\u2019s ranking. Fire accidents if not handled properly, may lead to a massive loss of life and assets. With a perspective [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":1936,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[256,164],"tags":[255],"acf":{"service_id":"259"},"authorName":"Shalini Singh","authorImageUrl":"https:\/\/corpbiz.io\/learning\/wp-content\/uploads\/2019\/09\/MEE.jpeg","authorDescription":"Shalini is a B.tech graduate but her keen interest in writing impelled her to continue as a content writer. Further, She has a rich experience in Companies Act and Ammendment related topics.","postViews":9349,"readingTime":5,"_links":{"self":[{"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/posts\/1935"}],"collection":[{"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/comments?post=1935"}],"version-history":[{"count":22,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/posts\/1935\/revisions"}],"predecessor-version":[{"id":65146,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/posts\/1935\/revisions\/65146"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/media\/1936"}],"wp:attachment":[{"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/media?parent=1935"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/categories?post=1935"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/corpbiz.io\/learning\/wp-json\/wp\/v2\/tags?post=1935"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}